Resistance thermometers, also called resistance temperature detectors (RTDs), are temperature sensors that exploit the predictable change in electrical resistance of some materials with changing temperature. As they're almost invariably made of platinum, they're often called platinum resistance thermometers (PRTs). They are slowly replacing the use of thermocouples in many industrial applications below 600 °C.

General description

There are two broad categories, "film" and "wire-wound" types.
  • Film thermometers have a layer of platinum on a substrate; the layer may be extremely thin, perhaps 1 micrometer. Advantages of this type are relatively low cost and fast response. Such devices have improved in performance although the different expansion rates of the substrate and platinum give "strain gauge" effects and stability problems.
  • Wire-wound thermometers can have greater accuracy, especially for wide temperature ranges. The coil diameter provides a compromise between mechanical stability and allowing expansion of the wire to minimize strain and consequential drift.
The current international standard which specifies tolerance and the temperature to electrical resistance relationship for platinum resistance thermometers is IEC 751:1983. By far the most common devices used in industry have a nominal resistance of 100 ohms at 0 °C, and are called Pt-100 sensors ('Pt' is the symbol for platinum). The sensitivity of a standard 100 ohm sensor is a nominal 0.385 ohm/°C. RTDs with a sensitivity of 0.375 and 0.392 ohm/°C are also available.

How do resistance thermometers work?

Resistance thermometers are constructed in a number of forms and offer greater stability, accuracy and repeatability in some cases than thermocouples. While thermocouples use the Seebeck effect to generate a voltage, resistance thermometers use electrical resistance and require a small power source to operate. The resistance ideally varies linearly with temperature.
   Resistance thermometers are usually made using platinum, because of its linear resistance-temperature relationship and its chemical inertness. The platinum detecting wire needs to be kept free of contamination to remain stable. A platinum wire or film is supported on a former in such a way that it gets minimal differential expansion or other strains from its former, yet is reasonably resistant to vibration. RTD assemblies made from iron or copper are also used in some applications.
   Commercial platinum grades are produced which exhibit a change of resistance of 0.385 ohms/°C (European Fundamental Interval) The sensor is usually made to have a resistance of 100Ω at 0 °C. This is defined in BS EN 60751:1996 (taken from IEC 60751:1995) . The American Fundamental Interval is 0.392 Ω/°C, based on using a purer grade of platinum than the European standard. The American standard is from the Scientific Apparatus Manufacturers Association (SAMA), who are no longer in this standards field.
   Resistance thermometers require a small current to be passed through in order to determine the resistance. This can cause resistive heating, and manufacturers' limits should always be followed along with heat path considerations in design. Care should also be taken to avoid any strains on the resistance thermometer in its application. Lead wire resistance should be considered, and adopting three and four wire connections can eliminate connection lead resistance effects from measurements - industrial practice is almost universally to use 3-wire connection. 4-wire connection need to be used for precise application.

Advantages and limitations

Advantages of platinum resistance thermometers:
  • High accuracy
  • Low drift
  • Wide operating range
  • Suitability for precision applications Limitations:
  • RTDs in industrial applications are rarely used above 660 °C. At temperatures above 660 °C it becomes increasingly difficult to prevent the platinum from becoming contaminated by impurities from the metal sheath of the thermometer. This is why laboratory standard thermometers replace the metal sheath with a glass construction. At very low temperatures, say below -270 °C (or 3 K), due to the fact that there are very few phonons, the resistance of an RTD is mainly determined by impurities and boundary scattering and thus basically independent of temperature. As a result, the sensitivity of the RTD is essentially zero and therefore not useful.
  • Compared to thermistors, platinum RTDs are less sensitive to small temperature changes and have a slower response time. However, thermistors have a smaller temperature range and stability.

    Resistance thermometer elements

    Resistance thermometer elements are available in a number of forms. The most common are:
  • Wire wound in a ceramic insulator - wire spiral within sealed ceramic cylinder, works with temperatures to 850 °C
  • Wire encapsulated in glass - wire around glass core with glass fused homogenously around, resists vibration, more protection to the detecting wire but smaller usable range
  • Thin film - platinum film on ceramic substrate, small and inexpensive to mass produce, fast response to temperature change

    Resistance thermometer construction

    These elements nearly always require insulated leads attached. At low temperatures PVC, silicon rubber or PTFE insulators are common to 250°C. Above this, glass fibre or ceramic are used. The measuring point and usually most of the leads require a housing or protection sleeve. This is often a metal alloy which is inert to a particular process. Often more consideration goes in to selecting and designing protection sheaths than sensors as this is the layer that must withstand chemical or physical attack and offer convenient process attachment points.

    Resistance thermometer wiring configurations

    Two-wire configuration

    The simplest resistance thermometer configuration uses two wires. It is only used when high accuracy isn't required as the resistance of the connecting wires is always included with that of the sensor leading to errors in the signal. Using this configuration you'll be able to use 100 metres of cable. This applies equally to balanced bridge and fixed bridge system.

    Three-wire configuration

    In order to minimize the effects of the lead resistances a three wire configuration can be used. Using this method the two leads to the sensor are on adjoining arms, there's a lead resistance in each arm of the bridge and therefore the lead resistance is cancelled out. High quality connection cables should be used for this type of configuration because an assumption is made that the two lead resistances are the same. This configuration allows for up to 600 meters of cable.

    Four-wire configuration

    The four wire resistance thermometer configuration even further increases the accuracy and reliability of the resistance being measured. In the diagram above a standard two terminal RTD is used with another pair of wires to form an additional loop that cancels out the lead resistance. The above Wheatstone bridge method uses a little more copper wire and isn't a perfect solution. Below is a better alternative configuration four-wire Kelvin connection that should be used in all RTDs. It provides full cancellation of spurious effects and cable resistance of up to 15 Ω can be handled. Actually in four wire measurement the resistance error due to lead wire resistance is zero.

    History

    The application of the tendency of electrical conductors to increase their electrical resistance with rising temperature was first described by Sir William Siemens at the Bakerian Lecture of 1871 before the Royal Society of Great Britain. The necessary methods of construction were established by Callendar, Griffiths, Holborn and Wein between 1885 and 1900.

    Standard resistance thermometer data

    Temperature sensors are usually supplied with thin-film elements. These are rated in accordance with BS EN 60751:1996 as:
    Tolerance Class alid Range
    Tolerance class B -70 to +500 °C
    Tolerance class A (1/2B) -30 to +350 °C
    Tolerance class 1/3B 0 to +100 °C
    Resistance thermometer elements can be supplied which function up to 850 °C. Sensor tolerances are calculated as:
    Tolerance Class emperature Deviation
    Class B t = ±(0.3+0.005|t|)
    Class A t = ±(0.15+0.0025|t|)
    1/3 DIN t = ±13 × (0.3+0.005|t|)
    1/5 DIN t = ±15 × (0.3+0.005|t|)
    1/10 DIN t = ±110 × (0.3+0.005|t|)
    where |t| = absolute value of temperature in °C. Where elements have a resistance of n x 100 Ω then the basic values and tolerances also have to be multiplied by n.

    Temperature to resistance equation

    The relation between temperature and resistance is given by the Callendar-Van Dusen equation, » R_T = R_0 left[ 1 + AT + BT^2 + CT^3 (T-100) ight] ; (-200;.

    Since the B and C coefficients are relatively small, the resistance changes almost linearly with the temperature.

    Values for various popular resistance thermometers

    Temperature
    in °C
    Pt100
    in Ω
    Pt1000
    in Ω
    PTC
    in Ω
    NTC
    in Ω
    NTC
    in Ω
    NTC
    in Ω
    NTC
    in Ω
    NTC
    in Ω
    Typ: 404 Typ: 501 Typ: 201 Typ: 101 Typ: 102 Typ: 103 Typ: 104 Typ: 105
    −50 80,31 803,1 1032
    −45 82,29 822,9 1084
    −40 84,27 842,7 1135 50475
    −35 86,25 862,5 1191 36405
    −30 88,22 882,2 1246 26550
    −25 90,19 901,9 1306 26083 19560
    −20 92,16 921,6 1366 19414 14560
    −15 94,12 941,2 1430 14596 10943
    −10 96,09 960,9 1493 11066 8299
    −5 98,04 980,4 1561 31389 8466
    0 100,00 1000,0 1628 23868 6536
    5 101,95 1019,5 1700 18299 5078
    10 103,90 1039,0 1771 14130 3986
    15 105,85 1058,5 1847 10998
    20 107,79 1077,9 1922 8618
    25 109,73 1097,3 2000 6800 15000
    30 111,67 1116,7 2080 5401 11933
    35 113,61 1136,1 2162 4317 9522
    40 115,54 1155,4 2244 3471 7657
    45 117,47 1174,7 2330 6194
    50 119,40 1194,0 2415 5039
    55 121,32 1213,2 2505 4299 27475
    60 123,24 1232,4 2595 3756 22590
    65 125,16 1251,6 2689 18668
    70 127,07 1270,7 2782 15052
    75 128,98 1289,8 2880 12932
    80 130,89 1308,9 2977 10837
    85 132,80 1328,0 3079 9121
    90 134,70 1347,0 3180 7708
    95 136,60 1366,0 3285 6539
    100 138,50 1385,0 3390
    105 140,39 1403,9
    110 142,29 1422,9
    150 157,31 1573,1
    200 175,84 1758,4
    Copied from german version, please don't remove
    Further Information

    Get more info on 'Resistance Temperature Detector'.


    External Link Exchanges

    Do you know how hard it is to get a link from a large encyclopaedia? Well we're different and will prove it. To get a link from us just add the following HTML to your site on a relevant page:

      <a href="http://resistance_thermometer.totallyexplained.com">Resistance thermometer Totally Explained</a>

    Then simply click through this link from your web page. Our crawlers will verify your link, extract the title of your web page and instantly add a link back to it. If you like you can remove the words Totally Explained and embed the link in article text.
       As long as your link remains in place, we'll keep our link to you right here. Please play fair - our crawlers are watching. Your site must be closely related to this one's topic. Any kind of spamming, dubious practises or removing the link will result in your link from us being dropped and, potentially, your whole site being banned.



  • Copyright © 2007-8 totallyexplained.com | Licensed under the GNU Free Documentation License | Site Map
    This article contains text from the Wikipedia article Resistance thermometer (History) and is released under the GFDL | RSS Version